Originální abstrakt

The basis for room air distribution solutions in ventilating and air conditioning rooms is the calcula-tion of velocities in air jets from supply outlets. To calculate velocities, the C-value of the air outlets must be known. The outlet C-values are specified for each type of outlet experimentally. The aim of this contribution is to acquaint readers with nontraditional methods for defining the C-value of an outlet from the angle of air jet expansion in the main jet zone, determined using interferometric visu-alization of the jet. To visualize the air jet from the outlet, a Mach-Zehnder interferometer is used which allows accurate, quality interferometric records to be obtained over the entire field of view of the jet. This contribution describes the dependence of the outlet C-value on the expansion angle of the main jet zone. The principles of interferometric measurements in transparent environments are dem-onstrated, along with their evaluation via special software developed for evaluating recorded inter-ferograms. The C-value of slot and rectangular outlets is determined using the method introduced here. Results demonstrate the high precision of the method, and that the C-values of outlets can be defined effectively from the visualization records.

Anglický abstrakt

The basis for room air distribution solutions in ventilating and air conditioning rooms is the calcula-tion of velocities in air jets from supply outlets. To calculate velocities, the C-value of the air outlets must be known. The outlet C-values are specified for each type of outlet experimentally. The aim of this contribution is to acquaint readers with nontraditional methods for defining the C-value of an outlet from the angle of air jet expansion in the main jet zone, determined using interferometric visu-alization of the jet. To visualize the air jet from the outlet, a Mach-Zehnder interferometer is used which allows accurate, quality interferometric records to be obtained over the entire field of view of the jet. This contribution describes the dependence of the outlet C-value on the expansion angle of the main jet zone. The principles of interferometric measurements in transparent environments are dem-onstrated, along with their evaluation via special software developed for evaluating recorded inter-ferograms. The C-value of slot and rectangular outlets is determined using the method introduced here. Results demonstrate the high precision of the method, and that the C-values of outlets can be defined effectively from the visualization records.

BibTex


@article{BUT46678,
  author="Eva {Janotková} and Milan {Pavelek}",
  title="Determination of air outlet C values by means of interferometry",
  annote="The basis for room air distribution solutions in ventilating and air conditioning rooms is the calcula-tion of velocities in air jets from supply outlets. To calculate velocities, the C-value of the air outlets must be known. The outlet C-values are specified for each type of outlet experimentally. The aim of this contribution is to acquaint readers with nontraditional methods for defining the C-value of an outlet from the angle of air jet expansion in the main jet zone, determined using interferometric visu-alization of the jet. To visualize the air jet from the outlet, a Mach-Zehnder interferometer is used which allows accurate, quality interferometric records to be obtained over the entire field of view of the jet. This contribution describes the dependence of the outlet C-value on the expansion angle of the main jet zone. The principles of interferometric measurements in transparent environments are dem-onstrated, along with their evaluation via special software developed for evaluating recorded inter-ferograms. The C-value of slot and rectangular outlets is determined using the method introduced here. Results demonstrate the high precision of the method, and that the C-values of outlets can be defined effectively from the visualization records.",
  address="VEETECH Ltd.",
  chapter="46678",
  institution="VEETECH Ltd.",
  journal="The international journal of ventilation",
  number="4",
  volume="4",
  year="2006",
  month="march",
  pages="311--322",
  publisher="VEETECH Ltd.",
  type="journal article - other"
}