Detail publikace

Elektrodes for elektrochromic devices studied by QCM

Originální název

Elektrodes for elektrochromic devices studied by QCM

Anglický název

Elektrodes for elektrochromic devices studied by QCM

Jazyk

en

Originální abstrakt

The mass of thin layer electrodes can be observed by the QCB method it is based on the changes of resonance frequency of a quartz crystal resonator. The investigated substance is deposited on the surface of the resonator. Various metals Pt, Au, Ag and their compounds should be plated on the resonator. Most frequently, the resonators for the frequency 5,0 MHz are used.The crystal surface with the layer is exposed to the electrolyte in a three electrode system, usually driven by a potentiostat. This frequency change is used for detection of chemical changes of the electrode surface. This system is very sensitive.

Anglický abstrakt

The mass of thin layer electrodes can be observed by the QCB method it is based on the changes of resonance frequency of a quartz crystal resonator. The investigated substance is deposited on the surface of the resonator. Various metals Pt, Au, Ag and their compounds should be plated on the resonator. Most frequently, the resonators for the frequency 5,0 MHz are used.The crystal surface with the layer is exposed to the electrolyte in a three electrode system, usually driven by a potentiostat. This frequency change is used for detection of chemical changes of the electrode surface. This system is very sensitive.

BibTex


@inproceedings{BUT24360,
  author="Vít {Svoboda} and Petr {Špičák} and Marie {Sedlaříková} and Jiří {Vondrák} and Jiří {Kazelle}",
  title="Elektrodes for elektrochromic devices studied by QCM",
  annote="The mass of thin layer electrodes can be observed by the QCB method  it is based on the changes of resonance frequency of a quartz crystal resonator. The investigated substance is deposited on the surface of the resonator. Various metals Pt, Au, Ag and their compounds should be plated on the resonator. Most frequently, the resonators for the frequency 5,0 MHz are used.The crystal surface with the layer is exposed to the electrolyte in a three  electrode system, usually driven by a potentiostat. This frequency change is used for detection of chemical changes of the electrode surface. This system is very sensitive.",
  booktitle="7 th ABA BRNO 2006 Advanced Batteries and Accumulators",
  chapter="24360",
  year="2006",
  month="april",
  pages="165",
  type="conference paper"
}