Originální abstrakt

The paper compares changes of important parameters of lead acid battery cell during discharge and charge by potential electrochemical impedance spectroscopy (PEIS) method measured in situ and ex situ. Nyquist diagrams were used for determination of ohmic and charge transfer resistance of lead acid battery cell.

Anglický abstrakt

The paper compares changes of important parameters of lead acid battery cell during discharge and charge by potential electrochemical impedance spectroscopy (PEIS) method measured in situ and ex situ. Nyquist diagrams were used for determination of ohmic and charge transfer resistance of lead acid battery cell.

BibTex


@inproceedings{BUT159277,
  author="Petr {Křivík} and Sebastian {Vaculík} and Petr {Bača} and Jiří {Kazelle}",
  title="In situ and ex situ measurements of lead acid battery cell by PEIS",
  annote="The paper compares changes of important parameters of lead acid battery cell
during discharge and charge by potential electrochemical impedance
spectroscopy (PEIS) method measured in situ and ex situ. Nyquist diagrams
were used for determination of ohmic and charge transfer resistance of lead
acid battery cell.",
  address="VUT v Brně",
  booktitle="ABAF- 20",
  chapter="159277",
  edition="1",
  howpublished="electronic, physical medium",
  institution="VUT v Brně",
  year="2019",
  month="september",
  pages="115--117",
  publisher="VUT v Brně",
  type="conference paper"
}