Comparing Saddle, Slotted-tube and Parallel-plate Coils for Magnetic Resonance Imaging

Originální název

Comparing Saddle, Slotted-tube and Parallel-plate Coils for Magnetic Resonance Imaging

Anglický název

Comparing Saddle, Slotted-tube and Parallel-plate Coils for Magnetic Resonance Imaging

Jazyk

en

Originální abstrakt

The paper is concerned with a comparison of the properties of RF coils of three configurations for MRI measurements on small animals. In comparison with the classical saddle coil the proposed modification of slotted-tube coil exhibits identical homogeneity of B1 field in a larger space. The parallel-plate coil has a satisfactory homogeneity of B1 field over the whole internal space. The signal-to-noise ratio measured for all three coils is roughly the same and is given by the magnitude of RF pre-amplifier noise. As the slotted-tube and parallel-plate coils have a lower inductance compared with the saddle coil, they can be tuned to resonance on the 200 MHz frequency even at larger dimensions. The results show that the parallel-plate coil has very good properties for the measurement of small animals.

Anglický abstrakt

The paper is concerned with a comparison of the properties of RF coils of three configurations for MRI measurements on small animals. In comparison with the classical saddle coil the proposed modification of slotted-tube coil exhibits identical homogeneity of B1 field in a larger space. The parallel-plate coil has a satisfactory homogeneity of B1 field over the whole internal space. The signal-to-noise ratio measured for all three coils is roughly the same and is given by the magnitude of RF pre-amplifier noise. As the slotted-tube and parallel-plate coils have a lower inductance compared with the saddle coil, they can be tuned to resonance on the 200 MHz frequency even at larger dimensions. The results show that the parallel-plate coil has very good properties for the measurement of small animals.

BibTex


@article{BUT111197,
  author="Karel {Bartušek} and Dušan {Nešpor} and Zdeněk {Dokoupil}",
  title="Comparing Saddle, Slotted-tube and Parallel-plate Coils for Magnetic Resonance Imaging",
  annote="The paper is concerned with a comparison of the properties of RF coils of three configurations for MRI measurements on small animals. In comparison with the classical saddle coil the proposed modification of slotted-tube coil exhibits identical homogeneity of B1 field in a larger space. The parallel-plate coil has a satisfactory homogeneity of B1 field over the whole internal space. The signal-to-noise ratio measured for all three coils is roughly the same and is given by the magnitude of RF pre-amplifier noise. As the slotted-tube and parallel-plate coils have a lower inductance compared with the saddle coil, they can be tuned to resonance on the 200 MHz frequency even at larger dimensions. The results show that the parallel-plate coil has very good properties for the measurement of small animals.",
  address="De Gruyter Open Sp. z o.o.",
  chapter="111197",
  doi="10.2478/msr-2014-0023",
  institution="De Gruyter Open Sp. z o.o.",
  number="1",
  volume="14",
  year="2014",
  month="december",
  pages="171--176",
  publisher="De Gruyter Open Sp. z o.o.",
  type="journal article in Web of Science"
}