Original Abstract

Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hydrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.

English abstract

Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hydrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer. The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide.

RIV year

2003

Released

01.01.2003

Publisher

Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií

Location

Brno

ISBN

80-214-2379-X

Book

Proceedings of 9th conference and competition Student EEICT 2003, Volume 3

Edition number

1

Pages from

440

Pages to

444

Pages count

5

Documents

BibTex


@inproceedings{BUT10486,
  author="Jiří {Háze}",
  title="PORTABLE DEVICE FOR PESTICIDE TOXICITY ANALYSIS",
  annote="Fast detection of pesticide toxicity in field conditions is not fully solved yet. The new device for field measurement of organophosporous pesticides toxicity is described. The detection is based on the inhibition of acetylcholinesterase. The enzyme acetylcholinesterase is immobilized on a miniature electrochemical detector made by thick film technology forming together a biosensor. The dimensions of biosensor are 7,35 x 25,4 mm. The biosensor is placed in flow chamber which assures the reproducible hydrodynamic conditions near of active surface of the sensor. The analyzed sample is detected in the flow of supporting buffer.
The biosensor detects the integral sample toxicity. It is destinated for detection of traces of pesticides in washout from leaves for direct measurment in rivers, ponds, vaste waters and drinking water sources. The preconcentration of sample is possible. The detection limit varies in wide range depending on the toxicity of pesticide. 
",
  address="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  booktitle="Proceedings of 9th conference and competition Student EEICT 2003, Volume 3",