Publication detail

Measurement of Biosignals and Subsequent Processing for More Accurate Determination of Cardiovascular System Parameters

ČÍŽ, R. ŘÍHA, K. ALKHEIR, J.

Original Title

Measurement of Biosignals and Subsequent Processing for More Accurate Determination of Cardiovascular System Parameters

English Title

Measurement of Biosignals and Subsequent Processing for More Accurate Determination of Cardiovascular System Parameters

Type

conference paper

Language

en

Original Abstract

The medical diagnostics currently uses a number of parameters which describe the condition of a patient's cardiovascular system. These parameters are derived from biosignal waveforms, often obtained in different time, under different factors of measurement, so these signals are affected by different level of distortion and noise. The accuracy of the computed parameters for the correct evaluation of the current condition, or progression of cardiovascular system is quite important. The paper describes, in detail, measurement of biosignals and subsequent processing which suppress the inaccuracy of a new method proposed for blood pressure determination.

English abstract

The medical diagnostics currently uses a number of parameters which describe the condition of a patient's cardiovascular system. These parameters are derived from biosignal waveforms, often obtained in different time, under different factors of measurement, so these signals are affected by different level of distortion and noise. The accuracy of the computed parameters for the correct evaluation of the current condition, or progression of cardiovascular system is quite important. The paper describes, in detail, measurement of biosignals and subsequent processing which suppress the inaccuracy of a new method proposed for blood pressure determination.

Keywords

Ultrasound Imaging, Image Processing, Cardiac Cycles Curve, Pulse Transit Time, Blood Pressure

RIV year

2013

Released

02.07.2013

Publisher

Brno University of Technology

Location

Brno

ISBN

978-1-4799-0403-7

Book

Proceedings of the 36th International Conference on Telecommunications and Signal Processing

Pages from

643

Pages to

647

Pages count

5

BibTex


@inproceedings{BUT100947,
  author="Radim {Číž} and Kamil {Říha} and Jafar {Alkheir}",
  title="Measurement of Biosignals and Subsequent Processing for More Accurate Determination of Cardiovascular System Parameters",
  annote="The medical diagnostics currently uses a number of parameters which describe the condition of a patient's cardiovascular system. These parameters are derived from biosignal waveforms, often obtained in different time, under different factors of measurement, so these signals are affected by different level of distortion and noise. The accuracy of the computed parameters for the correct evaluation of the current condition, or progression of cardiovascular system is quite important. The paper describes, in detail, measurement of biosignals and subsequent processing which suppress the inaccuracy of a new method proposed for blood pressure determination.",
  address="Brno University of Technology",
  booktitle="Proceedings of the 36th International Conference on Telecommunications and Signal Processing",
  chapter="100947",
  howpublished="electronic, physical medium",
  institution="Brno University of Technology",
  year="2013",
  month="july",
  pages="643--647",
  publisher="Brno University of Technology",
  type="conference paper"
}