Publication detail

The Device for Low-Cost Measurement of 2D Thermal Distribution

MINÁŘ, J. ŘÍHA, K.

Original Title

The Device for Low-Cost Measurement of 2D Thermal Distribution

English Title

The Device for Low-Cost Measurement of 2D Thermal Distribution

Type

journal article - other

Language

en

Original Abstract

The article describes a specialized device for measurement of thermal distribution of two dimensional surfaces for some applications in medical industry, and mechanical or civil engineering. The device is a substitution of expensive device for this kind of measurement is thermal camera which can be expensive for some application or should have the limitation of non-possibility to read temperature behind a barrier (wall, bandage).

English abstract

The article describes a specialized device for measurement of thermal distribution of two dimensional surfaces for some applications in medical industry, and mechanical or civil engineering. The device is a substitution of expensive device for this kind of measurement is thermal camera which can be expensive for some application or should have the limitation of non-possibility to read temperature behind a barrier (wall, bandage).

Keywords

measurment; temperature; thermistor; thernal distribution; real time

RIV year

2012

Released

05.12.2012

Location

Brno

ISBN

1805-5443

Periodical

International Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems

Year of study

1

Number

2-3

State

CZ

Pages from

49

Pages to

52

Pages count

4

Documents

BibTex


@article{BUT117035,
  author="Jiří {Minář} and Kamil {Říha}",
  title="The Device for Low-Cost Measurement of 2D Thermal Distribution",
  annote="The article describes a specialized device for measurement of thermal distribution of two dimensional surfaces for some applications in medical industry, and mechanical or civil engineering. The device is a substitution of expensive device for this kind of measurement is thermal camera which can be expensive for some application or should have the limitation of non-possibility to read temperature behind a barrier (wall, bandage).",
  chapter="117035",
  doi="10.11601/ijates.v1i2-3.38",
  howpublished="online",
  number="2-3",
  volume="1",
  year="2012",
  month="december",
  pages="49--52",
  type="journal article - other"
}