Detail publikace

The Fluid Flow in the T-Junction the Comparison of the Numerical Modelling and PIV Measurement

Originální název

The Fluid Flow in the T-Junction the Comparison of the Numerical Modelling and PIV Measurement

Anglický název

The Fluid Flow in the T-Junction the Comparison of the Numerical Modelling and PIV Measurement

Jazyk

en

Originální abstrakt

There is presented the fluid flow in the T-junction with the 90 degree angle of the adjacent branch and with the 50mm diameter of each branch, in this chapter. The flow is organized as a combining flow. It means that there are two inlet branches and only one outlet branch. There are two possible kinds of the flow combinations for this T-junction. The CFD calculations and the PIV measurements were done for both flow combinations. Its comparison is presented in this paper.

Anglický abstrakt

There is presented the fluid flow in the T-junction with the 90 degree angle of the adjacent branch and with the 50mm diameter of each branch, in this chapter. The flow is organized as a combining flow. It means that there are two inlet branches and only one outlet branch. There are two possible kinds of the flow combinations for this T-junction. The CFD calculations and the PIV measurements were done for both flow combinations. Its comparison is presented in this paper.

Plný text v Digitální knihovně

Dokumenty

BibTex


@article{BUT94241,
  author="Jaroslav {Štigler} and Roman {Klas} and Michal {Kotek} and Václav {Kopecký}",
  title="The Fluid Flow in the T-Junction the Comparison of the Numerical Modelling and PIV Measurement",
  annote="There is presented the fluid flow in the T-junction with the 90 degree angle of the adjacent branch and with the 50mm diameter of each branch, in this chapter. The flow is organized as a combining flow. It means that there are two inlet branches and only one outlet branch. There are two possible kinds of the flow combinations for this T-junction. The CFD calculations and the PIV measurements were done for both flow combinations. Its comparison is presented in this paper.",
  address="Elsevier",
  chapter="94241",
  doi="10.1016/j.proeng.2012.07.003",
  institution="Elsevier",
  number="1",
  volume="39",
  year="2011",
  month="september",
  pages="19--27",
  publisher="Elsevier",
  type="journal article - other"
}