Detail publikace

Photometrical Parameters of the Luminaire Used for Laboratory Measure of Low-Power Photovoltaic Modules

PAVELKA, T. PTÁČEK, M. BAXANT, P.

Originální název

Photometrical Parameters of the Luminaire Used for Laboratory Measure of Low-Power Photovoltaic Modules

Anglický název

Photometrical Parameters of the Luminaire Used for Laboratory Measure of Low-Power Photovoltaic Modules

Jazyk

en

Originální abstrakt

This paper deals with evaluation of light-technological parameters of the luminaire made for the purpose of laboratory assessment of low-power photovoltaic modules. Because it is necessary to know, how the photovoltaic module works with artificial lighting, the demands have to be compared with concrete light distribution of used luminaire. This measurement is performed in light laboratory in Department of Electrical Power Engineering. It is also necessary to know relations between natural and artificial light, which are also included in this paper. This data can provide the knowledge about the possibilities of evaluation of photovoltaic modules during laboratory measurement.

Anglický abstrakt

This paper deals with evaluation of light-technological parameters of the luminaire made for the purpose of laboratory assessment of low-power photovoltaic modules. Because it is necessary to know, how the photovoltaic module works with artificial lighting, the demands have to be compared with concrete light distribution of used luminaire. This measurement is performed in light laboratory in Department of Electrical Power Engineering. It is also necessary to know relations between natural and artificial light, which are also included in this paper. This data can provide the knowledge about the possibilities of evaluation of photovoltaic modules during laboratory measurement.

Dokumenty

BibTex


@inproceedings{BUT92192,
  author="Tomáš {Pavelka} and Michal {Ptáček} and Petr {Baxant}",
  title="Photometrical Parameters of the Luminaire Used for Laboratory Measure of Low-Power Photovoltaic Modules",
  annote="This paper deals with evaluation of light-technological parameters of the luminaire made for the purpose of laboratory assessment of low-power photovoltaic modules. Because it is necessary to know, how the photovoltaic module works with artificial lighting, the demands have to be compared with concrete light distribution of used luminaire. This measurement is performed in light laboratory in Department of Electrical Power Engineering. It is also necessary to know relations between natural and artificial light, which are also included in this paper. This data can provide the knowledge about the possibilities of evaluation of photovoltaic modules during laboratory measurement.",
  address="Brno University of Technology, Faculty of Electrical Engineering and Communication, Department of Electrical Power Engineering",
  booktitle="Proceedings of the 13th International Scientific Conference Electric Power Engineering 2012",
  chapter="92192",
  edition="First edition",
  howpublished="print",
  institution="Brno University of Technology, Faculty of Electrical Engineering and Communication, Department of Electrical Power Engineering",
  year="2012",
  month="may",
  pages="1181--1184",
  publisher="Brno University of Technology, Faculty of Electrical Engineering and Communication, Department of Electrical Power Engineering",
  type="conference paper"
}