Detail publikace

The Hazardous Factors of HURDIS Ceiling Structures

ŠIMŮNEK, P., SALAJKA, V., HRADIL, P., ŠTĚPÁNEK, P.

Originální název

The Hazardous Factors of HURDIS Ceiling Structures

Anglický název

The Hazardous Factors of HURDIS Ceiling Structures

Jazyk

en

Originální abstrakt

In the Czech Republic there were failures of the ceramics floor units Hurdis. Expansion (moisture and tempeature) of ceramics and concrete may have been one of the important cause of failure. Contribution deals with comparison of different loading states effects and with the determination of decisive states causing collapsing.

Anglický abstrakt

In the Czech Republic there were failures of the ceramics floor units Hurdis. Expansion (moisture and tempeature) of ceramics and concrete may have been one of the important cause of failure. Contribution deals with comparison of different loading states effects and with the determination of decisive states causing collapsing.

Dokumenty

BibTex


@inproceedings{BUT8788,
  author="Petr {Šimůnek} and Vlastislav {Salajka} and Petr {Hradil} and Petr {Štěpánek}",
  title="The Hazardous Factors of HURDIS Ceiling Structures",
  annote="In the Czech Republic there were failures of the ceramics floor units Hurdis. Expansion (moisture and tempeature) of ceramics and concrete may have been one of the important cause of failure. Contribution deals with comparison of different loading states effects and with the determination of decisive states causing collapsing.",
  address="Technická univerzita v Košiciach",
  booktitle="Proceedings of III. International Scientific Conference - Quality and Reliability in Building Industry",
  chapter="8788",
  institution="Technická univerzita v Košiciach",
  number="10",
  year="2003",
  month="january",
  pages="511--516",
  publisher="Technická univerzita v Košiciach",
  type="conference paper"
}