Detail publikace
THE EFFECT OF CYLINDRICAL TANK DEFORMATION ON FORWARD SOLUTION IN ELECTRICAL IMPEDANCE TOMOGRAPHY
DUŠEK, J. MIKULKA, J. MŰNSTEROVÁ, Z. PAŘÍLKOVÁ, J.
Originální název
THE EFFECT OF CYLINDRICAL TANK DEFORMATION ON FORWARD SOLUTION IN ELECTRICAL IMPEDANCE TOMOGRAPHY
Anglický název
THE EFFECT OF CYLINDRICAL TANK DEFORMATION ON FORWARD SOLUTION IN ELECTRICAL IMPEDANCE TOMOGRAPHY
Jazyk
en
Originální abstrakt
This article briefly discusses the impact of cylindrical tank deformations on the measured values as an input for reconstruction via electrical impedance tomography. The experimental part contains experimental measurement with dimensional deformation at Y-axis. The computation of forward model solution was performed by EIDORS library. Simulated and measured values were evaluated with respect to the shape deformations. The difference of measured values between original and deformed shape of tomograph was higher than we expected.
Anglický abstrakt
This article briefly discusses the impact of cylindrical tank deformations on the measured values as an input for reconstruction via electrical impedance tomography. The experimental part contains experimental measurement with dimensional deformation at Y-axis. The computation of forward model solution was performed by EIDORS library. Simulated and measured values were evaluated with respect to the shape deformations. The difference of measured values between original and deformed shape of tomograph was higher than we expected.
Dokumenty
BibTex
@inproceedings{BUT165658,
author="Jan {Dušek} and Jan {Mikulka} and Zuzana {Műnsterová} and Jana {Pařílková}",
title="THE EFFECT OF CYLINDRICAL TANK DEFORMATION ON FORWARD SOLUTION IN ELECTRICAL IMPEDANCE TOMOGRAPHY",
annote="This article briefly discusses the impact of cylindrical tank deformations on the measured values as an input for reconstruction via electrical impedance tomography. The experimental part contains experimental measurement with dimensional deformation at Y-axis. The computation of forward model solution was performed by EIDORS library. Simulated and measured values were evaluated with respect to the shape deformations. The difference of measured values between original and deformed shape of tomograph was higher than we expected.",
address="VUTIUM, Brno University of Tchnology",
booktitle="EUREKA 2020",
chapter="165658",
edition="neuv.",
howpublished="print",
institution="VUTIUM, Brno University of Tchnology",
number="1",
year="2020",
month="october",
pages="60--63",
publisher="VUTIUM, Brno University of Tchnology"
}