Detail publikace

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

AUBRY, J. BATES, O. BOEHM, C. PAULY, K. CHRISTENSEN, D. CUETO, C. GÉLAT, P. GUASCH, L. JAROŠ, J. JING, Y. JONES, R. LI, N. MARTY, P. MONTANARO, H. NEUFELD, E. PICHARDO, S. PINTON, G. PULKKINEN, A. STANZIOLA, A. THIELSCHER, A. TREEBY, B. VAN 'T WOUT, E.

Originální název

Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, forexample, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions.To allow intercomparison between the different modeling tools and techniques used by the community, aninternational working group was convened to formulate a set of numerical benchmarks. Here, these benchmarksare presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexityare defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull.Two transducer configurations are considered (a focused bowl and a plane piston operating at 500 kHz), giving atotal of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmarkresults. The models span a wide range of numerical techniques, including the finite-difference time-domainmethod, angular spectrum method, pseudospectral method, boundary-element method, and spectral-elementmethod. Good agreement is found between the models, particularly for the position, size, and magnitude of theacoustic focus within the skull. When comparing results for each model with every other model in a cross-comparison, the median values for each benchmark for the difference in focal pressure and position are less than10% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freelyavailable to facilitate further comparisons.

Klíčová slova

Transcranial Ultrasound Simulations, Wave Models, Benchmaks

Autoři

AUBRY, J.; BATES, O.; BOEHM, C.; PAULY, K.; CHRISTENSEN, D.; CUETO, C.; GÉLAT, P.; GUASCH, L.; JAROŠ, J.; JING, Y.; JONES, R.; LI, N.; MARTY, P.; MONTANARO, H.; NEUFELD, E.; PICHARDO, S.; PINTON, G.; PULKKINEN, A.; STANZIOLA, A.; THIELSCHER, A.; TREEBY, B.; VAN 'T WOUT, E.

Vydáno

16. 8. 2022

ISSN

1520-8524

Periodikum

Journal of the Acoustical Society of America

Ročník

152

Číslo

2

Stát

Spojené státy americké

Strany od

1003

Strany do

1019

Strany počet

17

URL

BibTex

@article{BUT178884,
  author="Jean-Francois {Aubry} and Oscar {Bates} and Christian {Boehm} and Kim Butts {Pauly} and Douglas {Christensen} and Carlos {Cueto} and Pierre {Gélat} and Lluis {Guasch} and Jiří {Jaroš} and Yun {Jing} and Rebecca {Jones} and Ningrui {Li} and Patrick {Marty} and Hazael {Montanaro} and Esra {Neufeld} and Samuel {Pichardo} and Gianmarco {Pinton} and Aki {Pulkkinen} and Antonio {Stanziola} and Axel {Thielscher} and Bradley {Treeby} and Elwin {van 't Wout}",
  title="Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models",
  journal="Journal of the Acoustical Society of America",
  year="2022",
  volume="152",
  number="2",
  pages="1003--1019",
  doi="10.1121/10.0013426",
  issn="1520-8524",
  url="https://asa.scitation.org/doi/10.1121/10.0013426"
}