Originální abstrakt
A simple gradient coils temperature controller for a gradient magnetic field system has been developed. In the application of modern fast magnetic resonance experiments it can maintain the temperature of gradient coils at a value of 21.2?C with a precision of 0.5?C and protect the gradient system against overloading by excessive short-circuit power. When the temperature and the maximum power are exceeded, it will disconnect all gradients and, simultaneously, signal this state to the operator. A gradient system complemented like this has been experimentally verified on a home-built 200 MHz Magnetic Resonance (MR) Tomography system with a 120 mm bore (with room temperature) in the Institute of Scientific Instruments, Academy of Sciences of the Czech Republic.
Anglický abstrakt
A simple gradient coils temperature controller for a gradient magnetic field system has been developed. In the application of modern fast magnetic resonance experiments it can maintain the temperature of gradient coils at a value of 21.2?C with a precision of 0.5?C and protect the gradient system against overloading by excessive short-circuit power. When the temperature and the maximum power are exceeded, it will disconnect all gradients and, simultaneously, signal this state to the operator. A gradient system complemented like this has been experimentally verified on a home-built 200 MHz Magnetic Resonance (MR) Tomography system with a 120 mm bore (with room temperature) in the Institute of Scientific Instruments, Academy of Sciences of the Czech Republic.
Dokumenty
BibTex
@inproceedings{BUT23330,
author="Karel {Bartušek} and Zdeněk {Dokoupil} and Eva {Gescheidtová}",
title="Gradient Coils Temperature Controller in a Gradient System for MR Tomography",
annote="A simple gradient coils temperature controller for a gradient magnetic field system has been developed. In the application of modern fast magnetic resonance experiments it can maintain the temperature of gradient coils at a value of 21.2?C with a precision of 0.5?C and protect the gradient system against overloading by excessive short-circuit power. When the temperature and the maximum power are exceeded, it will disconnect all gradients and, simultaneously, signal this state to the operator. A gradient system complemented like this has been experimentally verified on a home-built 200 MHz Magnetic Resonance (MR) Tomography system with a 120 mm bore (with room temperature) in the Institute of Scientific Instruments, Academy of Sciences of the Czech Republic.",
address="Žilinská univerzita",
booktitle="Reasearch in Telecomunication Technology 2007",
chapter="23330",
institution="Žilinská univerzita",
year="2007",
month="september",
pages="1--5",
publisher="Žilinská univerzita",
type="conference paper"
}