Detail publikace

CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection

VANĚČKOVÁ, T. BEZDĚKOVÁ, J. TVRDOŇOVÁ, M. VLČNOVSKÁ, M. NOVOTNÁ, V. NEUMAN, J. ŠTOSSOVÁ, A. KANICKÝ, V. ADAM, V. VACULOVIČOVÁ, M. VACULOVIČ, T.

Originální název

CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

For the first time, the combination of molecularly imprinted polymer (MIP) technology with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is presented with focus on an optimization of the LA-ICP-MS parameters such as laser beam diameter, laser beam fluence, and scan speed using CdS quantum dots (QDs) as a template and dopamine as a functional monomer. A non-covalent imprinting approach was employed in this study due to the simplicity of preparation. Simple oxidative polymerization of the dopamine that creates the self-assembly monolayer seems to be an ideal choice. The QDs prepared by UV light irradiation synthesis were stabilized by using mercaptosuccinic acid. Formation of a complex of QD-anti body and QD-antibody-antigen was verified by using capillary electrophoresis with laser-induced fluorescence detection. QDs and antibody were connected together via an affinity peptide linker. LA-ICP-MS was employed as a proof-of-concept for detection method of two types of immunoassay: 1) antigen extracted from the sample by MIP and subsequently overlaid/immunoreacted by QD-labelled antibodies, 2) complex of antigen, antibody, and QD formed in the sample and subsequently extracted by MIP. The first approach provided higher sensitivity (MIP/NIP), however, the second demonstrated higher selectivity. A mixture of proteins with size in range 10-250 kDa was used as a model sample to demonstrate the capability of both approaches for detection of IgG in a complex sample.

Klíčová slova

CdS quantum dots (QDs); molecularly imprinted polymer (MIP); laser ablation ICP-MS

Autoři

VANĚČKOVÁ, T.; BEZDĚKOVÁ, J.; TVRDOŇOVÁ, M.; VLČNOVSKÁ, M.; NOVOTNÁ, V.; NEUMAN, J.; ŠTOSSOVÁ, A.; KANICKÝ, V.; ADAM, V.; VACULOVIČOVÁ, M.; VACULOVIČ, T.

Vydáno

14. 8. 2019

Nakladatel

Springer Nature

ISSN

2045-2322

Periodikum

Scientific Reports

Ročník

9

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

1

Strany do

9

Strany počet

9

URL

Plný text v Digitální knihovně

BibTex

@article{BUT158577,
  author="Tereza {Vaněčková} and Jaroslava {Bezděková} and Michaela {Tvrdoňová} and Marcela {Vlčnovská} and Veronika {Novotná} and Jan {Neuman} and Aneta {Štossová} and Viktor {Kanický} and Vojtěch {Adam} and Markéta {Vaculovičová} and Tomáš {Vaculovič}",
  title="CdS quantum dots-based immunoassay combined with particle imprinted polymer technology and laser ablation ICP-MS as a versatile tool for protein detection",
  journal="Scientific Reports",
  year="2019",
  volume="9",
  number="1",
  pages="1--9",
  doi="10.1038/s41598-019-48290-2",
  issn="2045-2322",
  url="http://link.springer.com/article/10.1038/s41598-019-48290-2"
}