Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels

BALÁZS, I. MELCHER, J. BELICA, A. OLY, R. MISIEK, T.

Originální název

Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels

Typ

článek v časopise - ostatní, Jost

Jazyk

angličtina

Originální abstrakt

Sandwich panels supported by purlins are widely used as the main load bearing part of roof systems of the steel buildings. Sandwich panels provide lateral and rotational restraint to purlins which positively influences their resistance. Lateral restraint given by sandwich panels is equal for both downward load and uplift load applied on the panel’s surface, though the rotational restraint may have different character. The uplift load reduces contact area between the panels and purlins which can result in smaller restraint value. ECCS Publication No 135/CIB Publication 379 states, the rotational restraint for uplift shall be determined by tests with recommended setup, otherwise zero value has to be considered. The recommended setup, originally developed by Joachim Lindner, was also used for the large EASIE testing program, which was the base of the aforementioned recommendation. Test setup from EN 1993-1-3, originally developed by Teoman Peköz for tests with cold-formed purlins and corrugated sheeting, has been considered as inappropriate for sandwich panels because it does not consider effects from transverse load. During the EASIE test program only hot-rolled purlins were tested and therefore evaluation did not take into account section distortion (which is negligible for hot-rolled sections). Application of the test results for cold-formed purlins and conclusion related to the rotational restraint under uplift load therefore requires re-confirmation by tests with cold-formed purlins. Experimental research to determine the rotational restraint given to cold-formed Z purlins by sandwich panels was performed at Brno University of Technology (BUT) in cooperation with Astron Buildings S.A. (Astron). Tested were sandwich panels with direct fastening and hidden fastening, with PUR/PIR and mineral wool core. ECCS/CIB test setup with application of a torsional moment and a modified setup with application of a direct force were used. Several tests were additionally done with the setup described in EN 1993-1-3. Creep effect was investigated as well. Based on the tests results, the appropriate test setup for cold-formed purlins to determine the rotational restraints under uplift was proposed.

Klíčová slova

cold-formed purlins; experimental setup; rotational restraints; sandwich panels

Autoři

BALÁZS, I.; MELCHER, J.; BELICA, A.; OLY, R.; MISIEK, T.

Vydáno

13. 9. 2017

Nakladatel

Ernst & Sohn Verlag für Architektur und technische Wissenschaften GmbH & Co. KG

Místo

Berlin

ISSN

2509-7075

Periodikum

ce/papers

Ročník

1

Číslo

2-3

Stát

Spolková republika Německo

Strany od

1677

Strany do

1686

Strany počet

10

BibTex

@article{BUT139621,
  author="Ivan {Balázs} and Jindřich {Melcher} and Andrej {Belica} and René {Oly} and Thomas {Misiek}",
  title="Experimental setups for the measurement of the rotational restraint provided to cold-formed Z-purlins by sandwich panels",
  journal="ce/papers",
  year="2017",
  volume="1",
  number="2-3",
  pages="1677--1686",
  doi="10.1002/cepa.211",
  issn="2509-7075"
}