Originální abstrakt

This paper deals with a low power operation of small hydro power plants. It is typical for small hydro power plants on small rivers without reservoirs where the power in low season is less than one-third of nominal power. That is why the efficiency is decreased. The generator has low efficiency in this operation due to constant no load losses. The analysis of losses is presented and possible improvements are suggested. The last part of this paper presents a simple method of reducing no load losses, calculation of the power savings and experimental validation of this method.

Anglický abstrakt

This paper deals with a low power operation of small hydro power plants. It is typical for small hydro power plants on small rivers without reservoirs where the power in low season is less than one-third of nominal power. That is why the efficiency is decreased. The generator has low efficiency in this operation due to constant no load losses. The analysis of losses is presented and possible improvements are suggested. The last part of this paper presents a simple method of reducing no load losses, calculation of the power savings and experimental validation of this method.

BibTex


@inproceedings{BUT137077,
  author="Ondřej {Rubeš} and Dalibor {Červinka}",
  title="Efficiency Optimization of Small Hydro Power Plant in Low Power Operation",
  annote="This paper deals with a low power operation of small hydro power plants. It is typical for small hydro power plants on small rivers without reservoirs where the power in low season is less than one-third of nominal power. That is why the efficiency is decreased. The generator has low efficiency in this operation due to constant no load losses. The analysis of losses is presented and possible improvements are suggested. The last part of this paper presents a simple method of reducing no load losses, calculation of the power savings and experimental validation of this method.",
  address="Institute of Electrical and Electronics Engineers Inc.",
  booktitle="Conference Proceedings 2017 IEEE International Conference on Environment and Electrical Engineering",
  chapter="137077",
  doi="10.1109/EEEIC.2017.7977518",
  howpublished="electronic, physical medium",
  institution="Institute of Electrical and Electronics Engineers Inc.",
  year="2017",
  month="june",
  pages="717--721",
  publisher="Institute of Electrical and Electronics Engineers Inc.",
  type="conference paper"
}