Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification

Originální název

Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification

Anglický název

Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification

Jazyk

en

Originální abstrakt

In this work we utilized X-Trace LIBS device (AtomTrace, CZ) equipped with both, echelle and Czerny-Turner, spectrometers for the stand-off analysis (at the distance of 6.5 meters) of various sedimentary rocks. Then the multivariate data analysis (MVDA) algorithms (soft-independent modelling of class analogies, partial least squares discriminant analysis and Kohonen’s self-organizing maps) were applied for the classification of detected echelle and Czerny-Turner spectra. The obtained figure of merits overreached 99% of overall accuracy regardless of the analysis (utilized spectrometer or MVDA algorithm). To compare the sensitivity of both stand-off LIBS system adaptations, the limits of detection in respect to trace elements were estimated.

Anglický abstrakt

In this work we utilized X-Trace LIBS device (AtomTrace, CZ) equipped with both, echelle and Czerny-Turner, spectrometers for the stand-off analysis (at the distance of 6.5 meters) of various sedimentary rocks. Then the multivariate data analysis (MVDA) algorithms (soft-independent modelling of class analogies, partial least squares discriminant analysis and Kohonen’s self-organizing maps) were applied for the classification of detected echelle and Czerny-Turner spectra. The obtained figure of merits overreached 99% of overall accuracy regardless of the analysis (utilized spectrometer or MVDA algorithm). To compare the sensitivity of both stand-off LIBS system adaptations, the limits of detection in respect to trace elements were estimated.

Dokumenty

BibTex


@proceedings{BUT127010,
  author="Pavel {Pořízka} and David {Prochazka} and Jakub {Klus} and Jan {Novotný} and Markéta {Tesařová} and Jozef {Kaiser}",
  title="Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification",
  annote="In this work we utilized X-Trace LIBS device (AtomTrace, CZ) equipped with both, echelle and Czerny-Turner, spectrometers for the stand-off analysis (at the distance of 6.5 meters) of various sedimentary rocks. Then the multivariate data analysis (MVDA) algorithms (soft-independent modelling of class analogies, partial least squares discriminant analysis and Kohonen’s self-organizing maps) were applied for the classification of detected echelle and Czerny-Turner spectra. The obtained figure of merits overreached 99% of overall accuracy regardless of the analysis (utilized spectrometer or MVDA algorithm). To compare the sensitivity of both stand-off LIBS system adaptations, the limits of detection in respect to trace elements were estimated.",
  address="National institut of Chemistry Slovenia",
  booktitle="Book of Abstracts of the 13th European Workshop on Laser Ablation",
  chapter="127010",
  howpublished="print",
  institution="National institut of Chemistry Slovenia",
  year="2016",
  month="june",
  pages="109--109",
  publisher="National institut of Chemistry Slovenia",
  type="conference proceedings"
}