Detail publikace

MISO Universal Frequency Filter with Dual-Parameter Control of the Pole Frequency

Originální název

MISO Universal Frequency Filter with Dual-Parameter Control of the Pole Frequency

Anglický název

MISO Universal Frequency Filter with Dual-Parameter Control of the Pole Frequency

Jazyk

en

Originální abstrakt

This contribution presents a universal multiple-input single-output (MISO) filter with the dual-parameter control of the pole frequency. The current-mode filter is of the second order and the required type of the response (low pass, inverting band pass, high pass, band reject and all pass) is obtained by proper selection/combination of input(s). The filter employs two capacitors, two modified current differencing units (MCDUs), each of them with four controllable parameters, and one multiple-output current follower (MO-CF). Pole frequency of the filter is directly influenced by two adjustable parameters in frame of MCDU active elements.

Anglický abstrakt

This contribution presents a universal multiple-input single-output (MISO) filter with the dual-parameter control of the pole frequency. The current-mode filter is of the second order and the required type of the response (low pass, inverting band pass, high pass, band reject and all pass) is obtained by proper selection/combination of input(s). The filter employs two capacitors, two modified current differencing units (MCDUs), each of them with four controllable parameters, and one multiple-output current follower (MO-CF). Pole frequency of the filter is directly influenced by two adjustable parameters in frame of MCDU active elements.

BibTex


@inproceedings{BUT118756,
  author="Jan {Jeřábek} and Roman {Šotner} and Norbert {Herencsár} and Josef {Polák} and Jan {Dvořák} and Jaroslav {Koton}",
  title="MISO Universal Frequency Filter with Dual-Parameter Control of the Pole Frequency",
  annote="This contribution presents a universal multiple-input single-output (MISO) filter with the dual-parameter control of the pole frequency. The current-mode filter is of the second order and the required type of the response (low pass, inverting band pass, high pass, band reject and all pass) is obtained by proper selection/combination of input(s). The filter employs two capacitors, two modified current differencing units (MCDUs), each of them with four controllable parameters, and one multiple-output current follower (MO-CF). Pole frequency of the filter is directly influenced by two adjustable parameters in frame of MCDU active elements.",
  address="The Chamber of Electrical Engineers Bursa Branch",
  booktitle="ELECO 2015 9th International Conference on Electrical and Electronics Engineering",
  chapter="118756",
  doi="10.1109/ELECO.2015.7394535",
  howpublished="electronic, physical medium",
  institution="The Chamber of Electrical Engineers Bursa Branch",
  year="2015",
  month="november",
  pages="24--28",
  publisher="The Chamber of Electrical Engineers Bursa Branch",
  type="conference paper"
}