Detail publikace
Using of Argon-Hydrogen Plasma as a Tool for Removing of Corrosion Layers from Bronze Samples
FOJTÍKOVÁ, P. ŘÁDKOVÁ, L. JANOVÁ, D. KRČMA, F.
Originální název
Using of Argon-Hydrogen Plasma as a Tool for Removing of Corrosion Layers from Bronze Samples
Anglický název
Using of Argon-Hydrogen Plasma as a Tool for Removing of Corrosion Layers from Bronze Samples
Jazyk
en
Originální abstrakt
Our research is focused on application of low-pressure low-temperature plasma on corroded samples. In presented case, the bronze plates with dimension of 10 × 50 mm, were used as a samples. The process of corrosion layers creation taken place in the soil for 2 years at the ambient conditions and thus simulated natural process. The samples with corrosion layers were treated in the plasma chemical apparatus. The argon-hydrogen mixture was chosen as a working gas. The emission spectra were scanned every minute during the plasma treatment by the optical emission spectrometer. The samples were analysed by a scanning electron microscope (SEM) in order to obtain high resolution surface morphology and chemical composition by energy dispersive X-ray analysis (EDX).
Anglický abstrakt
Our research is focused on application of low-pressure low-temperature plasma on corroded samples. In presented case, the bronze plates with dimension of 10 × 50 mm, were used as a samples. The process of corrosion layers creation taken place in the soil for 2 years at the ambient conditions and thus simulated natural process. The samples with corrosion layers were treated in the plasma chemical apparatus. The argon-hydrogen mixture was chosen as a working gas. The emission spectra were scanned every minute during the plasma treatment by the optical emission spectrometer. The samples were analysed by a scanning electron microscope (SEM) in order to obtain high resolution surface morphology and chemical composition by energy dispersive X-ray analysis (EDX).
Dokumenty
BibTex
@misc{BUT116948,
author="Petra {Miková} and Lucie {Řádková} and Drahomíra {Janová} and František {Krčma}",
title="Using of Argon-Hydrogen Plasma as a Tool for Removing of Corrosion Layers from Bronze Samples",
annote="Our research is focused on application of low-pressure low-temperature plasma on corroded samples. In presented case, the bronze plates with dimension of 10 × 50 mm, were used as a samples. The process of corrosion layers creation taken place in the soil for 2 years at the ambient conditions and thus simulated natural process. The samples with corrosion layers were treated in the plasma chemical apparatus. The argon-hydrogen mixture was chosen as a working gas. The emission spectra were scanned every minute during the plasma treatment by the optical emission spectrometer. The samples were analysed by a scanning electron microscope (SEM) in order to obtain high resolution surface morphology and chemical composition by energy dispersive X-ray analysis (EDX).",
address="FCH VUT",
booktitle="Chemistry & Life 2015 - Book of Abstracts",
chapter="116948",
howpublished="print",
institution="FCH VUT",
year="2015",
month="september",
pages="176--176",
publisher="FCH VUT",
type="abstract"
}