SIMULATION AND VERIFICATION OF METHODS FOR PARTIAL DISCHARGE SOURCE LOCALIZATION
MYŠKA, R.
Originální název
SIMULATION AND VERIFICATION OF METHODS FOR PARTIAL DISCHARGE SOURCE LOCALIZATION
Český název
SIMULATION AND VERIFICATION OF METHODS FOR PARTIAL DISCHARGE SOURCE LOCALIZATION
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
cs
Originální abstrakt
This article deals with possibilities of localization of partial discharges (PD) in oil power transformers. Localization can be performed by means of analysis of UHF waveforms which are measured during activity of the partial discharges. The time differences of arrival (TDOA) of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in 3D space a minimum of four antennas has to be used, since the time of the PD occurrence is unknown. For localization purposes the system of nonlinear equations has to be solved. This can be performed by means of analytical or numerical methods. Both of the methods have their own advantages and disadvantages. The application of both approaches for signal source localization in measurement model will be presented in this paper. The methods will be compared in view of their suitability for a given configuration of antenna system
Český abstrakt
This article deals with possibilities of localization of partial discharges (PD) in oil power transformers. Localization can be performed by means of analysis of UHF waveforms which are measured during activity of the partial discharges. The time differences of arrival (TDOA) of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in 3D space a minimum of four antennas has to be used, since the time of the PD occurrence is unknown. For localization purposes the system of nonlinear equations has to be solved. This can be performed by means of analytical or numerical methods. Both of the methods have their own advantages and disadvantages. The application of both approaches for signal source localization in measurement model will be presented in this paper. The methods will be compared in view of their suitability for a given configuration of antenna system
Klíčová slova
partial discharges, TDOA
Rok RIV
2012
Vydáno
26.04.2012
Nakladatel
LITERA Brno
Místo
Brno, ČR
ISBN
978-80-214-4462-1
Kniha
Proceedings of the 18th Conference Student EEICT 2012
Strany od
273
Strany do
277
Strany počet
5
Dokumenty
BibTex
@inproceedings{BUT91570,
author="Radek {Myška}",
title="SIMULATION AND VERIFICATION OF METHODS FOR PARTIAL DISCHARGE SOURCE LOCALIZATION",
annote="This article deals with possibilities of localization of partial discharges (PD) in oil power transformers. Localization can be performed by means of analysis of UHF waveforms which are measured during activity of the partial discharges. The time differences of arrival (TDOA) of the waveforms related to transient process occurrence in the signals are the main input parameters for localization methods. In order to estimate the position of the signal source in 3D space a minimum of four antennas has to be used, since the time of the PD occurrence is unknown. For localization purposes the system of nonlinear equations has to be solved. This can be performed by means of analytical or numerical methods. Both of the methods have their own advantages and disadvantages. The application of both approaches for signal source localization in measurement model will be presented in this paper. The methods will be compared in view of their suitability for a given configuration of antenna system",
address="LITERA Brno",
booktitle="Proceedings of the 18th Conference Student EEICT 2012",
chapter="91570",
howpublished="print",
institution="LITERA Brno",
year="2012",
month="april",
pages="273--277",
publisher="LITERA Brno",
type="conference paper"
}