Detail publikace

A NEW SYSTEM FOR ELECTROANALYTICAL MASS SCREENING

Originální název

A NEW SYSTEM FOR ELECTROANALYTICAL MASS SCREENING

Anglický název

A NEW SYSTEM FOR ELECTROANALYTICAL MASS SCREENING

Jazyk

en

Originální abstrakt

The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Measured data are sent to user-friendly application in computer and analyzed or saved consequently.

Anglický abstrakt

The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Measured data are sent to user-friendly application in computer and analyzed or saved consequently.

BibTex


@inproceedings{BUT35375,
  author="Jaromír {Žák} and Jaromír {Hubálek} and René {Kizek}",
  title="A NEW SYSTEM FOR ELECTROANALYTICAL MASS SCREENING",
  annote="The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Measured data are sent to user-friendly application in computer and analyzed or saved consequently.",
  address="Mendelová univerzita v Brně",
  booktitle="X. Pracovní setkání fyzikálních chemiků a elektrochemiků",
  chapter="35375",
  howpublished="print",
  institution="Mendelová univerzita v Brně",
  year="2010",
  month="june",
  pages="278--280",
  publisher="Mendelová univerzita v Brně",
  type="conference paper"
}