Originální abstrakt

It was confirmed that light air ions have positive infuence on human health. For its appraisal it is necessary to know the concentration of air ions and air ion mobility spectrum. This spectrum is usually found out using the saturation characteristic measurement with a gerdien tube; another design option consists in the aspiration condenser with a segmented inner electrode. The second method is faster, but the resolution of air ion mobility spectrum shows worse characteristics.. This paper deals with the mathematical analysis and numerical modeling of saturation characteristic evaluation for this aspiration condenser with a segmented inner electrode. Using a combination of both methods may increase the resolution of air ion mobility spectrum, and the progress of measurement is still better than with the gerdien tube solution.

Anglický abstrakt

It was confirmed that light air ions have positive infuence on human health. For its appraisal it is necessary to know the concentration of air ions and air ion mobility spectrum. This spectrum is usually found out using the saturation characteristic measurement with a gerdien tube; another design option consists in the aspiration condenser with a segmented inner electrode. The second method is faster, but the resolution of air ion mobility spectrum shows worse characteristics.. This paper deals with the mathematical analysis and numerical modeling of saturation characteristic evaluation for this aspiration condenser with a segmented inner electrode. Using a combination of both methods may increase the resolution of air ion mobility spectrum, and the progress of measurement is still better than with the gerdien tube solution.

Dokumenty

BibTex


@inproceedings{BUT33961,
  author="Zdeněk {Roubal} and Miloslav {Steinbauer} and Zoltán {Szabó}",
  title="Modeling of Saturation Characteristic of an Aspiration Condenser",
  annote="It was confirmed that light air ions have positive infuence on human health. For its appraisal it is necessary to know the concentration of air ions and air ion mobility spectrum. This spectrum is usually found out using the saturation characteristic measurement with a gerdien tube; another design option consists in the aspiration condenser with a segmented inner electrode. The second method is faster, but the resolution of air ion mobility spectrum shows worse characteristics.. This paper deals with the mathematical analysis and numerical modeling of saturation characteristic evaluation for this aspiration condenser with a segmented inner electrode. Using a combination of both methods may increase the resolution of air ion mobility spectrum, and the progress of measurement is still better than with the gerdien tube solution.",
  address="The Electromagnetic Academy",
  booktitle="PIERS 2010 in Xi'an Proceedings",
  chapter="33961",
  howpublished="print",
  institution="The Electromagnetic Academy",
  number="2",
  year="2010",
  month="march",
  pages="216--220",
  publisher="The Electromagnetic Academy",
  type="conference paper"
}