Detail publikace

Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals

Originální název

Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals

Anglický název

Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals

Jazyk

en

Originální abstrakt

This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400 microS/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA.

Anglický abstrakt

This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400 microS/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA.

BibTex


@inproceedings{BUT22877,
  author="Jana {Procházková} and Zdenka {Kozáková} and František {Krčma}",
  title="Breakdown of DC Diaphragm Discharge in Solutions of Alkaline Metals",
  annote="This contribution shows results obtained from the electrical measurements of the DC diaphragm discharge with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400  microS/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA.",
  booktitle="Proceedings of ISPC XVIII",
  chapter="22877",
  year="2007",
  month="august",
  pages="30P-50",