Originální abstrakt

This contribution shows results obtained from the electrical measurements of the diaphragm discharge in liquids with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400 micro S/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA. Both voltage and current values at the breakdown were more or less constant in the particular region of selected conductivities (approximately 200-1400 micro S/cm), these values were only slightly decreasing (in the case of voltage) or increasing (in the case of current), respectively, with the increasing solution conductivity (i.e. electrolyte concentration).

Anglický abstrakt

This contribution shows results obtained from the electrical measurements of the diaphragm discharge in liquids with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400 micro S/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA. Both voltage and current values at the breakdown were more or less constant in the particular region of selected conductivities (approximately 200-1400 micro S/cm), these values were only slightly decreasing (in the case of voltage) or increasing (in the case of current), respectively, with the increasing solution conductivity (i.e. electrolyte concentration).

BibTex


@inproceedings{BUT22815,
  author="Jana {Procházková} and Zdenka {Kozáková} and František {Krčma}",
  title="Breakdown of the DC Diaphragm Discharge in Selected Water Solutions",
  annote="This contribution shows results obtained from the electrical measurements of the diaphragm discharge in liquids with the focus on the discharge ignition. The determined breakdown voltage beheld into the range of 1100-1300 V in wide range of studied solution conductivities (50-1400  micro S/cm) independently on the electrolyte kind, the recorded breakdown current was 20-50 mA. Both voltage and current values at the breakdown were more or less constant in the particular region of selected conductivities (approximately 200-1400  micro S/cm), these values were only slightly decreasing (in the case of voltage) or increasing (in the case of current), respectively, with the increasing solution conductivity (i.e. electrolyte concentration).",
  address="Ústav fyziky plazmatu AV ČR",
  booktitle="Proceedings of ICPIG XXVIII",
  chapter="22815",
  institution="Ústav fyziky plazmatu AV ČR",
  year="2007",
  month="july",
  pages="1086--1089",
  publisher="Ústav fyziky plazmatu AV ČR",
  type="conference paper"
}