Measured parameters of the three-axis gaussmeter

HEJTMÁNEK, T.

Originální název

Measured parameters of the three-axis gaussmeter

Anglický název

Measured parameters of the three-axis gaussmeter

Jazyk

en

Originální abstrakt

The purpose of this article is a measuring parameters of a gaussmeter with a three-axis measuring probe designed for magnetic field mapping. Commercially available gaussmeters have low frequency bandwidth for these purposes, and signals cannot be measured in synchronous detec-tion mode. Therefore, a suitable magnetic field sensor was selected and one channel of the device was designed and made. In particular, the higher bandwidth for three-axis measurement and the possibility of synchronous signal detection were taken into account. Attention will also be paid to designing a suitable mechanical design of the probe and the location of the sensors. The gaussmeter will be used for magnetic impedance tomography (MIT), which is reconstruction method of con-ductivity image. On the proposed device was performed measurements of frequency bandwidth, noise measuring of Hall probe and measuring constants of Hall generators. The properties were evaluated and compared with parameters of commercially available Gaussmeters.

Anglický abstrakt

The purpose of this article is a measuring parameters of a gaussmeter with a three-axis measuring probe designed for magnetic field mapping. Commercially available gaussmeters have low frequency bandwidth for these purposes, and signals cannot be measured in synchronous detec-tion mode. Therefore, a suitable magnetic field sensor was selected and one channel of the device was designed and made. In particular, the higher bandwidth for three-axis measurement and the possibility of synchronous signal detection were taken into account. Attention will also be paid to designing a suitable mechanical design of the probe and the location of the sensors. The gaussmeter will be used for magnetic impedance tomography (MIT), which is reconstruction method of con-ductivity image. On the proposed device was performed measurements of frequency bandwidth, noise measuring of Hall probe and measuring constants of Hall generators. The properties were evaluated and compared with parameters of commercially available Gaussmeters.

Dokumenty

BibTex


@inproceedings{BUT157771,
  author="Tomáš {Hejtmánek}",
  title="Measured parameters of the three-axis gaussmeter",
  annote="The purpose of this article is a  measuring parameters  of a  gaussmeter with a three-axis measuring  probe  designed  for  magnetic  field  mapping.  Commercially  available  gaussmeters  have low frequency bandwidth for these purposes, and signals cannot be measured in synchronous detec-tion mode. Therefore, a suitable magnetic field sensor was selected and one channel of the device was  designed  and  made.  In  particular,  the  higher  bandwidth  for  three-axis  measurement  and  the possibility of synchronous signal detection were taken into account. Attention will also be paid to designing a suitable mechanical design of the probe and the location of the sensors. The gaussmeter will  be  used for  magnetic  impedance  tomography  (MIT),  which  is reconstruction  method  of con-ductivity image.  On  the  proposed  device  was  performed  measurements  of  frequency  bandwidth, noise  measuring  of  Hall  probe  and measuring  constants  of  Hall  generators. The  properties  were evaluated and compared with parameters of commercially available Gaussmeters.",
  address="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  booktitle="Proceedings of the 25th Conference STUDENT EEICT 2019",
  chapter="157771",
  howpublished="electronic, physical medium",
  institution="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  year="2019",
  month="april",
  pages="718--722",
  publisher="Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií",
  type="conference paper"
}