Detail publikace

Pulsed Vertical-Electric-Dipole Excited Voltages on Transmission Lines Over a Perfect Ground—A Closed-Form Analytical Description

ŠTUMPF, M.

Originální název

Pulsed Vertical-Electric-Dipole Excited Voltages on Transmission Lines Over a Perfect Ground—A Closed-Form Analytical Description

Český název

Pulsed Vertical-Electric-Dipole Excited Voltages on Transmission Lines Over a Perfect Ground—A Closed-Form Analytical Description

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

cs

Originální abstrakt

Space–time analytical expressions for the vertical-electric-dipole excited load voltage response of a transmission line over a perfectly electrically conducting ground are derived. The problem is formulated with the aid of the electromagnetic reciprocity theorem of the time convolution type and subsequently solved analytically. It is demonstrated that the resulting closed-form formulas are readily applicable to calculating the lightning-induced voltages on overhead lines.

Český abstrakt

Space–time analytical expressions for the vertical-electric-dipole excited load voltage response of a transmission line over a perfectly electrically conducting ground are derived. The problem is formulated with the aid of the electromagnetic reciprocity theorem of the time convolution type and subsequently solved analytically. It is demonstrated that the resulting closed-form formulas are readily applicable to calculating the lightning-induced voltages on overhead lines.

Klíčová slova

Electromagnetic reciprocity; time-domain analysis; lightning EM pulse.

Vydáno

31.07.2018

Nakladatel

IEEE Antennas and Propagation Society

Místo

Piscataway, NJ, USA

Strany od

1656

Strany do

1658

Strany počet

3

URL

Dokumenty

BibTex


@article{BUT149531,
  author="Martin {Štumpf}",
  title="Pulsed Vertical-Electric-Dipole Excited Voltages on Transmission Lines Over a Perfect Ground—A Closed-Form Analytical Description",
  annote="Space–time analytical expressions for the vertical-electric-dipole excited load voltage response of a transmission line over a perfectly electrically conducting ground are derived. The problem is formulated with the aid of the electromagnetic reciprocity theorem of the time convolution type and subsequently solved analytically. It is demonstrated that the resulting closed-form formulas are readily applicable to calculating the lightning-induced voltages on overhead lines.",
  address="IEEE Antennas and Propagation Society",
  chapter="149531",
  doi="10.1109/LAWP.2018.2861563",
  howpublished="online",
  institution="IEEE Antennas and Propagation Society",
  number="9",
  volume="17",
  year="2018",
  month="july",
  pages="1656--1658",
  publisher="IEEE Antennas and Propagation Society",
  type="journal article in Web of Science"
}