Originální abstrakt

In our experiment the electrical parameters that affect early somatic embryos (ESEs) were investigated. High voltage was generated by a special high voltage generator. High voltages ranging from 5 to 20 kV and frequency of 1Hz were applied longitudinal and transversal directly on the Petri dish with 2 days old ESEs of Picea abies for periods of 3 hours every day. One Petri dish was placed directly on top of the high voltage generator and on the other petri dish were fixed two copper plates for transmission of high voltage. Petri dishes were exposed to high voltage for 14 days. After this time, the influence of high voltage was evaluated.

Anglický abstrakt

In our experiment the electrical parameters that affect early somatic embryos (ESEs) were investigated. High voltage was generated by a special high voltage generator. High voltages ranging from 5 to 20 kV and frequency of 1Hz were applied longitudinal and transversal directly on the Petri dish with 2 days old ESEs of Picea abies for periods of 3 hours every day. One Petri dish was placed directly on top of the high voltage generator and on the other petri dish were fixed two copper plates for transmission of high voltage. Petri dishes were exposed to high voltage for 14 days. After this time, the influence of high voltage was evaluated.

BibTex


@misc{BUT114601,
  author="Eliška {Vlachová Hutová} and Petr {Marcoň} and Karel {Bartušek}",
  title="Effect of high voltage on the development of the plant tissue",
  annote="In our experiment the electrical parameters that affect early somatic embryos (ESEs) were
investigated. High voltage was generated by a special high voltage generator. High voltages
ranging from 5 to 20 kV and frequency of 1Hz were applied longitudinal and transversal directly
on the Petri dish with 2 days old ESEs of Picea abies for periods of 3 hours every day. One Petri
dish was placed directly on top of the high voltage generator and on the other petri dish were fixed
two copper plates for transmission of high voltage. Petri dishes were exposed to high voltage for
14 days. After this time, the influence of high voltage was evaluated.",
  address="Electrotechnical Institute 28 Pozaryskiego Str. 04-703 Warsaw, Poland",
  booktitle="IIPHDW2015 Book of abstracts",
  chapter="114601",
  howpublished="print",
  institution="Electrotechnical Institute 28 Pozaryskiego Str. 04-703 Warsaw, Poland",
  year="2015",
  month="may",
  pages="33--33",
  publisher="Electrotechnical Institute 28 Pozaryskiego Str. 04-703 Warsaw, Poland",
  type="abstract"
}