Detail publikace
Robustness Evaluation of Corner Detectors for Use in Ultrasound Image Processing
ZUKAL, M. ČÍKA, P. QIU, X. BENEŠ, R.
Originální název
Robustness Evaluation of Corner Detectors for Use in Ultrasound Image Processing
Anglický název
Robustness Evaluation of Corner Detectors for Use in Ultrasound Image Processing
Jazyk
en
Originální abstrakt
This article deals with evaluation of suitability of interest point detectors (specifically corner detectors) for utilization in ultrasound image processing. Namely, the Harris detector, FAST (Features from Accelerated Segment Test) detector and Kanade-Lucas-Tomasi (KLT) detector have been tested on two data sets of ultrasound (US) images. The evaluation process consists of three experiments in which the images have been artificially corrupted by different types of noise or their brightness has been uniformly changed. The FAST detector proved to be more robust against noise than Harris and KLT detectors whereas the Harris and KLT detector outperformed FAST detector in case of brightness change.
Anglický abstrakt
This article deals with evaluation of suitability of interest point detectors (specifically corner detectors) for utilization in ultrasound image processing. Namely, the Harris detector, FAST (Features from Accelerated Segment Test) detector and Kanade-Lucas-Tomasi (KLT) detector have been tested on two data sets of ultrasound (US) images. The evaluation process consists of three experiments in which the images have been artificially corrupted by different types of noise or their brightness has been uniformly changed. The FAST detector proved to be more robust against noise than Harris and KLT detectors whereas the Harris and KLT detector outperformed FAST detector in case of brightness change.
Dokumenty
BibTex
@inproceedings{BUT100710,
author="Martin {Zukal} and Petr {Číka} and Xintao {Qiu} and Radek {Beneš}",
title="Robustness Evaluation of Corner Detectors for Use in Ultrasound Image Processing",
annote="This article deals with evaluation of suitability of interest point detectors (specifically corner detectors) for utilization in ultrasound image processing. Namely, the Harris detector, FAST (Features from Accelerated Segment Test) detector and Kanade-Lucas-Tomasi (KLT) detector have been tested on two data sets of ultrasound (US) images. The evaluation process consists of three experiments in which the images have been artificially corrupted by different types of noise or their brightness has been uniformly changed.
The FAST detector proved to be more robust against noise than Harris and KLT detectors whereas the Harris and KLT detector outperformed FAST detector in case of brightness change.",
booktitle="36th International Conference on Telecommunications and Signal Processing",
chapter="100710",
howpublished="electronic, physical medium",
year="2013",
month="july",
pages="763--767",
type="conference paper"
}