Influence of Lead Vapor Traces on Post-Discharge of Pure Nitrogen

KRČMA, F. HRDLIČKA, A. KANICKÝ, V. OTRUBA, V. KRÁSENSKÝ, P.

Original Title

Influence of Lead Vapor Traces on Post-Discharge of Pure Nitrogen

English Title

Influence of Lead Vapor Traces on Post-Discharge of Pure Nitrogen

Type

conference paper

Language

en

Original Abstract

The DC flowing post-discharge was used for the experimental study. The active discharge was created in a Pyrex or quartz discharge tubes with a 120 mm electrode distance at current of 200 mA and pressure of 700 Pa. The lead vapor was introduced into the discharge tube just befo an active discharge. Significant quenching of all nitrogen band was observed proportionally to the lead evaporating power.

English abstract

The DC flowing post-discharge was used for the experimental study. The active discharge was created in a Pyrex or quartz discharge tubes with a 120 mm electrode distance at current of 200 mA and pressure of 700 Pa. The lead vapor was introduced into the discharge tube just befo an active discharge. Significant quenching of all nitrogen band was observed proportionally to the lead evaporating power.

Keywords

nitrogen post-discharge, lead traces, optical emission spectroscopy

RIV year

2008

Released

15.07.2008

Publisher

Madrid University

Location

Madrid

ISBN

2-914771-04-5

Book

Europhysics Conference Abstracts 32A, Proceedings of ESCAMPIG XIX

Edition

Europhysics Conference Abstracts

Pages from

P-1-14-1

Pages to

P-1-14-2

Pages count

2

BibTex


@inproceedings{BUT31668,
  author="František {Krčma} and Aleš {Hrdlička} and Viktor {Kanický} and Vítězslav {Otruba} and Pavel {Krásenský}",
  title="Influence of Lead Vapor Traces on Post-Discharge of Pure Nitrogen",
  annote="The DC flowing post-discharge was used for the experimental study. The active discharge was created in a Pyrex or quartz discharge tubes with a 120 mm electrode distance at current of 200 mA and pressure of 700 Pa. The lead vapor was introduced into the discharge tube just befo an active discharge. Significant quenching of all nitrogen band was observed proportionally to the lead evaporating power.",
  address="Madrid University",
  booktitle="Europhysics Conference Abstracts 32A, Proceedings of ESCAMPIG XIX",
  chapter="31668",
  edition="Europhysics Conference Abstracts",
  howpublished="electronic, physical medium",
  institution="Madrid University",
  year="2008",
  month="july",
  pages="P-1-14-1--P-1-14-2",
  publisher="Madrid University",
  type="conference paper"
}