Original Abstract

The paper describes restitution of geometrical distortions and improvement of signal-to-noise ratio of auto-fluorescence retinal images, finally aimed at segmentation and area estimation of the lipofuscin spots as one of the features to be included in glaucoma diagnosis. The main problems – geometrical and illumination incompatibility of frames in the image sequence and a non-negligible shear distortion in the individual frames – have been solved by the presented registration procedure. The concept and some details of the MI-based regularized registration, together with evaluation of test results form the core of the contribution.

Czech abstract

Příspěvek se zabývá restitucí geometrického zkreslení a zlepšením poměru signálu k šumu u autofluorescenčních obrazů sítnice, s konečným cílem segmentace a odhadu velikosti oblastí lipofuscinu jako jedním z příznaků glaukomu. Podstatným problémem je přitom nekompatibilita snímků z posloupnosti v důsledku střihového zkreslení obrazů. Příspěvek popisuje koncept metody založené na užití kritéria vzájemné informace a současně informuje i o výsledcích testů.

English abstract

The paper describes restitution of geometrical distortions and improvement of signal-to-noise ratio of auto-fluorescence retinal images, finally aimed at segmentation and area estimation of the lipofuscin spots as one of the features to be included in glaucoma diagnosis. The main problems – geometrical and illumination incompatibility of frames in the image sequence and a non-negligible shear distortion in the individual frames – have been solved by the presented registration procedure. The concept and some details of the MI-based regularized registration, together with evaluation of test results form the core of the contribution.

Keywords

image registration, mutual information, noise, flexible transforms, retinal images, autofluorescence images

RIV year

2006

Released

01.08.2006

Publisher

IEEE

Location

New York

ISBN

1-4244-0033-3

Book

Proc. 28th IEEE/EMBS Ann.Intern. Conf. 2006

Edition number

1

Pages from

1948

Pages to

1951

Pages count

4

URL

knihovna ÚBMI FEKT VUT

BibTex


@inproceedings{BUT24215,
  author="Libor {Kubečka} and Jiří {Jan} and Radim {Kolář} and Radovan {Jiřík}",
  title="Elastic Registration for Auto-fluorescence Image Averaging",
  annote="The paper describes restitution of geometrical distortions and improvement of signal-to-noise ratio of auto-fluorescence retinal images, finally aimed at segmentation and area estimation of the lipofuscin spots as one of the features to be included in glaucoma diagnosis. The main problems – geometrical and illumination incompatibility of frames in the image sequence and a non-negligible shear distortion in the individual frames – have been solved by the presented registration procedure. The concept and some details of the MI-based regularized registration, together with evaluation of test results form the core of the contribution.",
  address="IEEE",
  booktitle="Proc. 28th IEEE/EMBS Ann.Intern. Conf. 2006",
  chapter="24215",
  institution="IEEE",
  year="2006",
  month="august",
  pages="1948",
  publisher="IEEE",
  type="conference paper"
}