Publication detail

Single Chip Measurement System for Control Responses from TFT Sensors

P. Steffan, R. Prokop, L. Fujcik ,R. Vrba

Original Title

Single Chip Measurement System for Control Responses from TFT Sensors

Czech Title

Čip pro měření odezvy z biosenzorů

English Title

Single Chip Measurement System for Control Responses from TFT Sensors

Type

conference paper

Language

en

Original Abstract

This paper focuses to deals with the design of a single chip measurement system for control responses from TFT biosensors. This monolitic measurement system exploits amperometric sensors. The sensor applies alumina substrate prepared by thick film technology. The ASIC prototype in CMOS 0.7 µm technology contains analog measurement block and programmable digital calibration EPROM memory on one chip.

Czech abstract

Článek se zabývá návrhem integrovaného měřicího systému vhodného pro měření s biozenzory. Měřicí systém je navržen v technologie CMOS 0,7 µm a obsahuje digitální a analogovou část.

English abstract

This paper focuses to deals with the design of a single chip measurement system for control responses from TFT biosensors. This monolitic measurement system exploits amperometric sensors. The sensor applies alumina substrate prepared by thick film technology. The ASIC prototype in CMOS 0.7 µm technology contains analog measurement block and programmable digital calibration EPROM memory on one chip.

Keywords

ASIC, measurement system

RIV year

2006

Released

23.04.2006

Publisher

IEEE Computer Society

Location

Mauritius

ISBN

0-7695-2552-0

Book

International Conference on Systems

Edition number

1.

Pages from

107

Pages to

111

Pages count

4

BibTex


@inproceedings{BUT18537,
  author="Pavel {Šteffan} and Roman {Prokop} and Lukáš {Fujcik} and Radimír {Vrba}",
  title="Single Chip Measurement System for Control Responses from TFT Sensors",
  annote="This paper focuses to deals with the design of a single chip measurement system for control responses from TFT biosensors. This monolitic measurement system exploits amperometric sensors. The sensor applies alumina substrate prepared by thick film technology. The ASIC prototype in CMOS 0.7 µm technology contains analog measurement block and programmable digital calibration EPROM memory on one chip.",
  address="IEEE Computer Society",
  booktitle="International Conference on Systems",
  chapter="18537",
  howpublished="electronic, physical medium",
  institution="IEEE Computer Society",
  year="2006",
  month="april",
  pages="107--111",
  publisher="IEEE Computer Society",
  type="conference paper"
}