Publication detail

Progress of the IR measurement in the area of the fine particulate material water content

SVĚRÁK, T. Baker, G. J. CH. SIKOROVÁ, K. KEJÍK, P. BULEJKO, P. KRIŠTOF, O.

Original Title

Progress of the IR measurement in the area of the fine particulate material water content

English Title

Progress of the IR measurement in the area of the fine particulate material water content

Type

conference paper

Language

en

Original Abstract

The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus

English abstract

The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of: the time of the spectral data that are taken; the influence of the false IR radiation; the influence of smoothness of the measured powder material surface; the distance of the measured material surface of the spectral measurement device focus

Keywords

moisture content, fine particulate material, infrared spectra

RIV year

2014

Released

19.12.2014

Publisher

Institute of Research Engineers and Doctors,

Location

USA

ISBN

978-1-63248-033-0

Book

Proceedings of the 2nd International Conference on Advances in Applied Science and Environmental Engineering

Pages from

20

Pages to

23

Pages count

4

BibTex


@inproceedings{BUT111745,
  author="Tomáš {Svěrák} and Kateřina {Mayerová} and Pavel {Kejík} and Pavel {Bulejko} and Ondřej {Krištof}",
  title="Progress of the IR measurement in the area of the fine particulate material water content",
  annote="The paper compares the results of the test of continuous moisture content measurements of lime hydrate under operating unit production conditions where the infra-red spectroscopy method and the classical method of the mass-decrease of samples in drying chamber were employed. The large differences which two measurement systems show are explained in connection of the changes of the measurement process conditions. The paper shows the taken data of infrared spectral measurement of the powder material moisture content as the function of:
 the time of the spectral data that are taken;
the influence of the false IR radiation;
the influence of smoothness of the measured powder material surface;
the distance of the measured material surface of the spectral measurement device focus",
  address="Institute of Research Engineers and Doctors,",
  booktitle="Proceedings of the 2nd International Conference on Advances in Applied Science and Environmental Engineering",
  chapter="111745",
  doi="10.15224/978-1-63248-033-0-05",
  howpublished="electronic, physical medium",
  institution="Institute of Research Engineers and Doctors,",
  year="2014",
  month="december",
  pages="20--23",
  publisher="Institute of Research Engineers and Doctors,",
  type="conference paper"
}