Original Abstract

This paper is focused on the description and comparison the alternative photometric and radiometric methods for liquid dielectric quality diagnostic and parameters measurement, long-term practical verification and comparison of obtained data with conventional methods. The proper function and accuracy of the measured methods are verified in the Light Laboratory and in the CVVOZEPowerLab in Brno University of Technology.

English abstract

This paper is focused on the description and comparison the alternative photometric and radiometric methods for liquid dielectric quality diagnostic and parameters measurement, long-term practical verification and comparison of obtained data with conventional methods. The proper function and accuracy of the measured methods are verified in the Light Laboratory and in the CVVOZEPowerLab in Brno University of Technology.

Keywords

Liquid Dielectric; Mineral Oil; Silicone Liquid; Spectroradiometer; Spectrum; UV-vis; Spectroscopy; D-lamp

Released

26.04.2019

Publisher

PRZEGLĄD ELEKTROTECHNICZNY

Location

Warsaw, Poland

ISBN

0033-2097

Periodical

Przeglad Elektrotechniczny

Year of study

6/2019

Number

04

State

PL

Pages from

15

Pages to

22

Pages count

8

URL

Documents

BibTex


@article{BUT157194,
  author="Michal {Krbal} and Jaroslav {Štěpánek} and Luděk {Pelikán} and Jaroslava {Orságová} and Iraida {Kolcunová}",
  title="Comparison of Electric and Radiometric Methods for Liquid Dielectric Diagnostic",
  annote="This paper is focused on the description and comparison the alternative photometric and radiometric methods for liquid dielectric quality diagnostic and parameters measurement, long-term practical verification and comparison of obtained data with conventional methods. The proper function and accuracy of the measured methods are verified in the Light Laboratory and in the CVVOZEPowerLab in Brno University of Technology.",
  address="PRZEGLĄD ELEKTROTECHNICZNY",
  chapter="157194",
  doi="10.15199/48.2019.06.04",
  howpublished="online",
  institution="PRZEGLĄD ELEKTROTECHNICZNY",
  number="04",
  volume="6/2019",
  year="2019",
  month="april",
  pages="15--22",
  publisher="PRZEGLĄD ELEKTROTECHNICZNY",
  type="journal article in Scopus"
}