Publication detail

Development of Cyber-physical security testbedbased on IEC61850 architecture

BLAŽEK, P. FUJDIAK, R. MLÝNEK, P. MIŠUREC, J.

Original Title

Development of Cyber-physical security testbedbased on IEC61850 architecture

English Title

Development of Cyber-physical security testbedbased on IEC61850 architecture

Type

journal article in Web of Science

Language

en

Original Abstract

The paper focuses on security in industrial control systems. Numerous protocols and their incompatibility are undermining the security design. Also, the IEC 61850 standard focuses on these issues; in detail, it deals with the compatibility between protocols and, partly security. In the context of this work, a testbed together with traffic generator was designed for IEC 61850 standard and its three main parts – MMS (Manufacturing Message Specification), GOOSE (Generic Object Oriented Substation Events) and Sampled Values. Additionally, the used generator was compared with an example of an RTU (Remote Terminal Unit) unit used in standard ICS (Industrial control systems) networks. The last part of this work consisted of performance testing of the implemented protocols (MMS, GOOSE, Sampled Values).

English abstract

The paper focuses on security in industrial control systems. Numerous protocols and their incompatibility are undermining the security design. Also, the IEC 61850 standard focuses on these issues; in detail, it deals with the compatibility between protocols and, partly security. In the context of this work, a testbed together with traffic generator was designed for IEC 61850 standard and its three main parts – MMS (Manufacturing Message Specification), GOOSE (Generic Object Oriented Substation Events) and Sampled Values. Additionally, the used generator was compared with an example of an RTU (Remote Terminal Unit) unit used in standard ICS (Industrial control systems) networks. The last part of this work consisted of performance testing of the implemented protocols (MMS, GOOSE, Sampled Values).

Keywords

SCADA;ICS; Attack; Generator; IEC 61850; Security

Released

10.06.2019

Publisher

Kaunas University of Technology

ISBN

1392-1215

Periodical

Elektronika Ir Elektrotechnika

Year of study

25

Number

5

State

LT

Pages from

82

Pages to

87

Pages count

6

URL

Full text in the Digital Library

Documents

BibTex


@article{BUT155261,
  author="Petr {Blažek} and Radek {Fujdiak} and Petr {Mlýnek} and Jiří {Mišurec}",
  title="Development of Cyber-physical security testbedbased on IEC61850 architecture",
  annote="The paper focuses on security in industrial control systems. Numerous protocols and their incompatibility are undermining the security design. Also, the IEC 61850 standard focuses on these issues; in detail, it deals with the compatibility between protocols and, partly security. In the context of this work, a testbed together with traffic generator was designed for IEC 61850 standard and its three main parts – MMS (Manufacturing Message Specification), GOOSE (Generic Object Oriented Substation Events) and Sampled Values. Additionally, the used generator was compared with an example of an RTU (Remote Terminal Unit) unit used in standard ICS (Industrial control systems) networks. The last part of this work consisted of performance testing of the implemented protocols (MMS, GOOSE, Sampled Values).",
  address="Kaunas University of Technology",
  chapter="155261",
  doi="10.5755/j01.eie.25.5.24361",
  howpublished="online",
  institution="Kaunas University of Technology",
  number="5",
  volume="25",
  year="2019",
  month="june",
  pages="82--87",
  publisher="Kaunas University of Technology",
  type="journal article in Web of Science"
}