Publication detail

SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION

HRNČÍŘOVÁ, M. ŠPILÁČEK, M. POSPÍŠIL, J.

Original Title

SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION

English Title

SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION

Type

journal article in Scopus

Language

en

Original Abstract

This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.

English abstract

This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.

Keywords

solid, particles, biomass

RIV year

2014

Released

28.02.2014

Publisher

Czech Technical University in Prague

Location

Prague

Pages from

22

Pages to

27

Pages count

6

Documents

BibTex


@article{BUT107982,
  author="Michaela {Hrnčířová} and Michal {Špiláček} and Jiří {Pospíšil}",
  title="SIZE ANALYSIS OF SOLID PARTICLES AT THE EXPERIMENTAL DEVICE FOR MULTI-STAGE BIOMASS COMBUSTION",
  annote="This paper presents the results of an analysis of ash content particles produced in biomass combustion at an experimental device. The main parts of the device are: the water heater, the gasifying chamber, the air preheater, and the fuel feeder. This device can be modified for combustion in an oxygen-enriched atmosphere. Sawdust and wood chips were used as fuel, and were laid loosely into the device. Ash specimens were extracted from various parts of the device. For the measurements themselves, we used the Analysette 22 MicroTec Plus universal laser diffraction device manufactured by the Fritch Company, in the size range from 0.08 micro meter to 2000 micro meter. The device utilizes laser diffraction for particle size analysis.",
  address="Czech Technical University in Prague",
  chapter="107982",
  doi="10.14311/AP.2014.54.0022",
  institution="Czech Technical University in Prague",
  number="1",
  volume="54",
  year="2014",
  month="february",
  pages="22--27",
  publisher="Czech Technical University in Prague",
  type="journal article in Scopus"
}